Standard Concrete Grades & Applications

Every construction project requires specific compressive strength and durability ratings. Below is our complete British Standard mix design matrix for domestic, commercial, and agricultural installations:

Standard Designation Equivalent Strength Primary Construction Uses Recommended Slump
GEN 1 / C10 10 N/mm² @ 28 Days Non-structural blinding layers, kerb backing, unreinforced drainage bedding S2 – S3 (50 - 150mm)
GEN 2 / C15 15 N/mm² @ 28 Days Unreinforced strip footings, patio sub-bases, light garden pathways S2 – S3 (50 - 150mm)
GEN 3 / C20 20 N/mm² @ 28 Days Domestic internal floor slabs without embedment, shallow foundations, garage bases S3 – S4 (100 - 200mm)
RC25/30 (C25) 25 N/mm² @ 28 Days Reinforced house extension footings, retaining walls, domestic driveways, raft foundations S3 (100 - 150mm)
RC30/37 (C30) 30 N/mm² @ 28 Days Heavy vehicular driveways, commercial yards, reinforced suspended slabs, external pavements S3 – S4 (100 - 200mm)
RC35/45 (C35 / C40) 35 - 40 N/mm² @ 28 Days Industrial warehouse floors, agricultural silage clamps, CFA piling, harsh environmental exposure S3 – S4 (100 - 200mm)

Custom Admixtures & Performance Enhancers

Because our volumetric mobile mixers blend dry ingredients at your Hatfield site, we can introduce specialized admixtures directly into the mixing auger to achieve precise workability and setting characteristics:

Polypropylene Structural Fibres

Micro and macro synthetic fibres disbursed uniformly throughout the concrete mix eliminate the need for crack-control steel mesh in standard slabs, reducing plastic shrinkage cracking by over 80%.

Setting Accelerators & Retarders

During cold winter pours, setting accelerators speed up early hydration to prevent frost damage. In hot summer weather, retarders extend open finishing time by up to 3 hours.

Waterproof & SBR Additives

Integral waterproofing admixtures block capillary pore channels, making the concrete completely impermeable to groundwater for basement retaining walls, swimming pools, and lift pits.

Plasticisers & Superplasticisers

Improves fluidity and self-levelling flow around dense steel reinforcement cages without adding excess water, preserving maximum structural compressive strength.

Workers laying volumetric ready mixed concrete in Hatfield

Slump Class Guide & Placement Workability

Slump represents the consistency and flow of wet concrete. We calibrate water-to-cement ratios on site to match your exact placement method:

Slump Class Target True Slump Ideal Placement Application
S1 (Semi-Dry) 10 – 40 mm Kerb laying, road gullies, dry-pack bedding, mass trench fill
S2 (Stiff) 50 – 90 mm Sloped foundations, ramp construction, simple hand-tamped slabs
S3 (Standard Flow) 100 – 150 mm Normal direct chute discharge, standard wheelbarrowing, strip footings
S4 (High Flow) 160 – 210 mm Ground line and boom pumping, complex reinforced formwork
S5 (Self-Compacting) ≥ 220 mm Specialist flowable foundations, underpinning, restricted flow pours